Home » Product List » BATTERY CHARGER PSU » 55W Battery Charger Switching Power Supply (AD55 With UPS Function)
Product Details
55W Battery Charger Switching Power Supply (AD55 With UPS Function)
| Packing: | Export Packing |
|---|---|
| Model NO.: | AD |
| Standard: | 55 |
| Productivity: | 50000PCS/Month |
| Trademark: | Sino-Amigo or OEM or Neutral Packing |
| Origin: | China |
| Output Type: | Dual |
| Output Power: | 51 - 100W |
| Input Voltage: | Full Range |
| Export Markets: | North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe |
Product Description
High Efficiency, High Reliability, Low Cost
100% Full Load Burn-In Test
Protections: Short circuit/Over load/Over voltage
LED Indicator For Power On
Cooling By Free Air Convection
Approvals: CE RoHS
Battery low and battery polarity protection
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 45KHz
| SPECIFICATION: | |||||
| MODEL | AD-55A | AD-55B | |||
| OUTPUT | DC VOLTAGE | 13.8V | 13.4V | 27.6V | 26.5V |
| RATED CURRENT | 3.5A | 0.23A | 1.8A | 0.16A | |
| CURRENT RANGE | 0 ~ 4A | ---------- | 0 ~ 2A | ---------- | |
| RATED POWER | 51.38W | 53.92W | |||
| RIPPLE & NOISE (max.) Note.2 | 50mVp-p | ---------- | 100mVp-p | ---------- | |
| VOLTAGE ADJ. RANGE | CH1:12 ~ 14.5V | CH1:24 ~ 29V | |||
| VOLTAGE TOLERANCE Note.3 | ±1.0% | ---------- | ±1.0% | ---------- | |
| LINE REGULATION | ±0.5% | ---------- | ±0.5% | ---------- | |
| LOAD REGULATION | ±0.5% | ---------- | ±0.5% | ---------- | |
| SETUP, RISE, HOLD TIME | 800ms,50ms, 80ms/230VAC 1600ms,50ms, 16ms/115VAC at full load | ||||
| INPUT | VOLTAGE RANGE | 85 ~ 264VAC 240 ~ 370VDC | |||
| FREQUENCY RANGE | 47 ~ 63Hz | ||||
| EFFICIENCY (Typ.) | 71% | 74% | |||
| AC CURRENT | 1.6A/115VAC 1A/230VAC | ||||
| INRUSH CURRENT (max.) | COLD START 20A/115VAC 40A/230VAC | ||||
| LEAKAGE CURRENT | <1mA / 240VAC | ||||
| PROTECTION | OVERLOAD | 105 ~ 150% rated output power. | |||
| Protection type: Hiccup mode, recovers automatically after fault condition is removed | |||||
| OVER VOLTAGE | CH1:14.49 ~ 18.63V | CH1:28.98 ~ 37.26V | |||
| Protection type: Hiccup mode, recovers automatically after fault condition is removed | |||||
| FUNCTION | DC ALARM SIGNAL(OPTIONAL) | AC fail CN1 PIN2 | |||
| Batterylow under charge voltage 82.5% 2% CN1 PIN1 | |||||
| Normal 0.8V max. Abnormal 5V 0.5V | |||||
| ENVIRONMENT | WORKING TEMP. | -10 ~ +60ºC (Refer to output load derating curve) | |||
| WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||
| STORAGE TEMP., HUMIDITY | -20 ~ +85ºC , 10 ~ 95% RH | ||||
| TEMP. COEFFICIENT | ±0.03%/ºC (0 ~ 50ºC) on CH1 output | ||||
| VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | ||||
| SAFETY & EMC | SAFETY STANDARDS | Design refer to UL60950-1, TUV EN60950-1 | |||
| WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||
| ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | ||||
| EMI CONDUCTION & RADIATION | Compliance to EN55022 (CISPR22) Class B | ||||
| HARMONIC CURRENT | Compliance to EN61000-3-2,-3 | ||||
| EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024,Light industry level, criteria A | ||||
| OTHERS | MTBF | 304.3K hrs min. MIL-HDBK-217F (25ºC) | |||
| DIMENSION | 159*97*38mm (L*W*H) | ||||
| PACKING | 0.492Kg; 30pcs/16.37Kg/0.0250CMB | ||||
| NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation. |
||||
Inquiry Basket (