Home » Product List » MULTIPLE OUTPUT PSU » 60W Dual Output Switching Power Supply (D-60 With Full Range Input)
Product Details
60W Dual Output Switching Power Supply (D-60 With Full Range Input)
| Packing: | Export Packing |
|---|---|
| Model NO.: | D |
| Standard: | 60 |
| Productivity: | 50000/Month |
| Shipment Terms: | by Sea, by Air, by Train,by Express |
| Payment Terms: | L/C,T/T |
| Minimum Order: | 20 Pieces |
| Trademark: | Sino-Amigo |
| Origin: | China |
| Output Type: | Dual |
| Output Power: | 51 - 100W |
| Input Voltage: | 90~132vac/176~264vac Selected by Switch |
| Export Markets: | North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe |
Product Description
High Efficiency, High Reliability, Low Cost
AC Input Range: Full Range
100% Full Load Burn-In Test
Protections: Short Circuit / Over Load/Over Voltage
LED Indicator For Power On
Cooling By Free Air Convection
Approvals: CE RoHS
1 Year Warranty
Dimensions: 159*98*38mm
| Model | D-60A | D-60B | ||
| CH1 | CH2 | CH1 | CH2 | |
| DC output voltage | 5V | 12V | 5V | 24V |
| Output voltage range | ±2% | ±6% | ±2% | ±5% |
| Rated output current | 4A | 3A | 3A | 1.8A |
| Output current range | 0.3-6A | 0.2-4A | 0.3-6A | 0.2-2.2A |
| Wave and noise | 75mVp-p | 150mVp-p | 75mVp-p | 150mVp-p |
| Inlet stability | ±0.5% | ±1% | ±0.5% | ±1% |
| Load stability | ±0.5% | ±4% | ±0.5% | ±4% |
| DC output power | 56W | 58W | ||
| Efficiency | 73% | 73% | ||
| Adjustable range for DC voltage | CH1; +10, -5% | CH1; +10, -5% | ||
| AC input voltage range | 85~264VAC ,47~63Hz;120~370VDC | |||
| Input current | 2A/115V 1A/230V | |||
| AC inrush current | Cold-start current 30A//115V,60A/230V | |||
| Leakage current | <1mA/240VAC | |||
| Overload protection | 105%~150% Type: pulsing hiccup shutdown Reset: auto recovery | |||
| Over-voltage protection | CH1: 5.75~6.75V | |||
| Temperature coefficient | ±0.03%/°c(0~50°c)ON+5V | |||
| Setup, rise , hold up time | 200ms,50ms, 20ms | |||
| Vibration | 10~500Hz, 2G 10min,/1cycle, Period for 60min, Each axes | |||
| Withstand voltage | Input and output internal: Input and encolsur: 1.5KvAC, Output and enclosure: 0.5KvAC | |||
| Isolation resistance | Input and output internal: Input and enclosure, Output and enclosure:500VDC/100MΩ | |||
| Working temperature and humidity | -10°c~+60°c(Refer to output derating curve), 20%~90%RH | |||
| Overall dimension | 159×97×38mm | |||
| Weight | 0.55Kgs | |||
| Safety standards | UL 1950 TUV EN60590 | |||
| EMC standards | CISPR22(EN55022)class B, IEC801-2,3,4 IEC555-2 Verification | |||
|
Note: 1. The testing condition for the paramenter above is: 230VAC input, rated load, 25 °c70% RH. Tempetature. 2. Error. include the setting error, line stability and load stability. 3. Wave test: adopting "A12" double wire for 20MHz, and 0.1 uf&47UF capacitor short-cicuit for interrupting. 4. Inler woltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage. 5. Load stability test: The load is from 0% to 100%. 6. Total output canba maxinum Current, total load can not exceed the maxium output power. |
||||