High Efficiency, High Reliability, Low Cost
AC Input Range: 90~264Vac 47~63Hz
100% Full Load Burn-In Test
Protections: Short Circuit / Over Load/Over Voltage
Cooling By Free Air Convection
Approvals: CE RoHS
1 Year Warranty
Dimension: 127*76*28mm
SPECIFICATION:
MODEL
PS-65-3.3
PS-65-5
PS-65-7.5
PS-65-12
PS-65-13.5
PS-65-15
PS-65-24
PS-65-27
PS-65-48
OUTPUT
DC VOLTAGE
3.3V
5V
7.5V
12V
13.5V
15V
24V
27V
48V
RATED CURRENT
12A
12A
8A
5.2A
4.7A
4.2A
2.7A
2.4A
1.35A
CURRENT RANGE
0 ~ 15.2A
0 ~ 13.8A
0 ~ 9.6A
0 ~ 6A
0 ~ 5.4A
0 ~ 4.8A
0 ~ 3A
0 ~ 2.7A
0 ~ 1.5A
RATED POWER
39.6W
60W
60W
62.4W
63.5W
63W
64.8W
64.8W
64.8W
OUTPUT POWER (max.)
Rated output power for convection;72W (+3.3V:35W) with 18 CFM min.Forced air
Protection type: Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
3.8 ~ 4.46V
5.75 ~ 6.75V
8.63 ~ 10.1V
13.8 ~ 16.2V
15.5 ~ 18.2V
17.25~ 20.25V
27.6 ~ 32.4V
31 ~ 36.45V
55.2 ~ 64.8V
Protection type: Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENT
WORKING TEMP.
-10 ~ +60ºC (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-20 ~ +85ºC, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.04%/ºC (0 ~ 50ºC)
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC(Note.4)
SAFETY STANDARDS
Design refer to UL60950-1,TUV EN60950-1
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION
Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; Light industry level, criteria A
OTHERS
MTBF
300.7Khrs min. MIL-HDBK-217F(25ºC)
DIMENSION
127*76*42mm (L*W*H)
PACKING
0.21Kg;54pcs/14.2Kg/1.35CUFT
NOTE
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation.
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
5.Mounting holes M1 and M2 should be grounded for EMI purposes.